chipskittles

I'm Awesome
Joined
Mar 20, 2013
Messages
183
Reaction score
43
what else could be wrong? overcharged?

It could be so much, that's why I keep asking for more information. Your pressures are about dead on. I'd be curious what the lines going into and out of the evaporator feel like when the system is running. They should be very cold leaving the evaporator
 
Joined
May 29, 2017
Messages
31
Reaction score
11
Location
Puyallup WA
It could be so much, that's why I keep asking for more information. Your pressures are about dead on. I'd be curious what the lines going into and out of the evaporator feel like when the system is running. They should be very cold leaving the evaporator

exactly why I asked about the blend door. Doesn't matter how perfect everything is if you don't actually blow all the air through the evaporator.
 

98vortec

OBS Enthusiast
Joined
Aug 7, 2017
Messages
76
Reaction score
4
Location
oklahoma
how can i check to make sure blend door is closing? which one is the heat/cold one?
 
Joined
May 29, 2017
Messages
31
Reaction score
11
Location
Puyallup WA
Decent video about the 3 different actuators. Mode, hot/cold and re-circulation actuators.

xc_hide_links_from_guests_guests_error_hide_media
 
Last edited:
Joined
May 29, 2017
Messages
31
Reaction score
11
Location
Puyallup WA
Another good vid. Click the link in the center to go directly to youtube. The actuator he's showing up in the right fwd corner is the re-circ actuator and that actuator could definitely be your problem.

xc_hide_links_from_guests_guests_error_hide_media
 
Last edited:

Tom P

I'm Awesome
Joined
Jan 29, 2017
Messages
374
Reaction score
79
Location
Washington
Another quick way to check how well the system is working is to physically touch the AC lines. After a few minutes of use the receiver drier should be cold and sweaty. Check the temps on the condenser out line before and after the orifice tube location. before the orifice it should be hot and after the orifice it should be ice cold. Especially with the ambient temps you are having right now, the differentials should be easy to determine.

** Edit **
This will be a good way to determine if the issue is in your blend door or actually in the A/C system itself. If your lines do not cool down within a minute or two then you'll know the issue is under the hood and not necessarily in the cab.
 
Joined
May 29, 2017
Messages
31
Reaction score
11
Location
Puyallup WA
True, he should put his hands on the lines coming out of the evaporator. Both should be very cold and should be sweating within a few minutes of run time. The accumulator should sweat and the suction line all the way to the pump should be cold and sweating.

Given the fact he's replaced 90% of the system, pulled a vacuum and recharged the system with the appropriate amount of refrigerant and the pressures are correct, I feel it's safe to say the problem is not under the hood. Given the complexity of the hvac module, I'd be looking there next. Check those vids out above for info on the hvac module. Good stuff in there.
 